Thermosetting enclosure 840x400x250mm IP44 for compensator 10/15/20 kVar

Thermosetting enclosure 840x400x250mm IP44 for compensator 10/15/20 kVar
Thermosetting enclosure 840x400x250mm IP44 for compensator 10/15/20 kVar
Thermosetting enclosure 840x400x250mm IP44 for compensator 10/15/20 kVar
Thermosetting enclosure 840x400x250mm IP44 for compensator 10/15/20 kVar
Thermosetting enclosure 840x400x250mm IP44 for compensator 10/15/20 kVar
Thermosetting enclosure 840x400x250mm IP44 for compensator 10/15/20 kVar
Thermosetting enclosure 840x400x250mm IP44 for compensator 10/15/20 kVar
Product is available
6 pcs.
Free shipping
See more
Buy now, we'll ship today!
To the end:

Details
ID1007014
ConditionNowy

Product description

1. General information

Device name:
Thermosetting enclosure with ventilation and heating.

Application:
Maintaining appropriate temperature conditions inside the enclosure through automatic heating and ventilation.

Power supply voltage:
230V AC / 50 Hz

2. List of components

  • Thermosetting enclosure 840x400x320 mm IP44 SSTN 40x84
  • Semiconductor heater 50W for DIN rail DN-151S-G060W
  • Overcurrent switch 1P B 6A 6kA xPole Home HN-B6/1 (194818)
  • 2-wire terminal block 16/25 mm² blue EURO 43403BL
  • Protective terminal block 16 mm² green-yellow ZSO1-16.0 (14603319)
  • Double thermostat (heating/cooling) TBGZ41 (86.41)
  • Fan with filter WEF7
  • Installation wires 1.5 mm² (L, N, PE)

3. Description of operation

The system implements automatic temperature control inside the cabinet:

  • Heating element turns on at temperatures below 10°C
  • Fan turns on at temperatures above 40°C
  • Control is done through a double thermostat

Power is supplied from the 230V AC network through the overcurrent switch.

4. Operation diagram (connection description)

  • Power L (phase) led through the overcurrent switch
  • From the switch:
    • to the thermostat input
  • Thermostat:
    • contacts 11–12 → control of the heater
    • contacts 23–24 → control of the fan
  • Neutral wire (N):
    • split by the terminal block
    • common for heater and fan
  • Protective wire (PE):
    • connected to the heater
    • then to the protective terminal (PE)

5. Safety measures

  • Overcurrent switch B6A
  • Protective grounding (PE)
  • Enclosure protection class IP44

6. Operating conditions

  • Ambient temperature: in accordance with the components used
  • Mounting: indoor / outdoor (according to IP44)
  • Operating position: vertical

7. User instructions

  1. Connect the device to the 230V AC installation.
  2. Check the correctness of the connection of wires L, N, PE.
  3. Do not obstruct the ventilation openings.
  4. Do not interfere with the electrical system while operating.
  5. In case of damage, disconnect the power supply.

8. Maintenance

  • Periodic inspection of electrical connections
  • Cleaning of the fan filter
  • Checking the operation of the thermostat

9. Final remarks

A set of components in a technical enclosure, intended to operate as part of an electrical installation.
The product is not a final product; it requires connection of supply wires.
Installation and connection should be performed by a qualified person.

Attributes

ConditionNowy

Documents

    KARTA INFORMACYJNA Obudowy male fundament

Reviews

0/5
0 reviews
5
0
4
0
3
0
2
0
1
0
You must sign in to add feedback